Q543. In 98.233.d.8 are we allowed to assume that volume fraction of CO2 content in natural gas out of the AGR unit is zero?
A543. No. §98.233(d)(8) does not instruct reporters to assume a volumetric fraction of zero for Vol0. Reporters must use one of the methods specified in §98.233(d)(8) to determine the CO2 content of the natural gas exiting the AGR unit (Vol0).
Updated on
Source: EPA, Frequently Asked Questions, Petroleum and Natural Gas Systems, July 2011, http://www.epa.gov/ghgreporting/documents/pdf/2011/documents/Subpart-W-additional-faq.pdf. Updated to clarify subscripts
Approval / Publishing History: Version 2, approved by M. Eaddy, 6/4/2012
Expiration : none
Relevant Subpart: W, Acid Gas Removal