Q100. When does moisture content need to be corrected for in Equation HH-4?

A100. If CH4 concentration and flow are both measured on a wet basis or both measured on a dry basis, then no moisture correction is needed. If one is measured on a wet basis and the other on a dry basis, then correction is needed.  Wiki Markup{show-to:group=confluence-Users}{_}Footer / References Bar which is Visible to the public{_}{show-to}


Show If
special@authenticated
Footer / References Bar which is Visible to the public
Panel

Updated on

Page info
infoTypemodified-Modified date
typemodified-dateFlat
dateformatdd/MM/YY HH:mm

...

Show If
special@authenticated
Info

Source: This question and answer was derived from a Legacy FAQ, revised by R. Schmeltz,

...